Biological Safety Exhaust Protection Filtration System
AIC-PFBSEE Series
Filtration Grade / Efficiency: Pre-filter (inlet panel) + HEPA high-efficiency filter (EN1822 H14 efficiency; dry seal or gel seal optional); PAO test penetration <0.01% (ISO14644)
Specifications / Dimensions: Box dimensions 735×665×660~690×940×670mm; rectangular duct connection dimensions 250×200~500×200mm
Rated Air Volume: 500~1700 m³/h (air volume codes 05/10/17×100)
Other Key Parameters: Box pressure bearing ±2500Pa (no obvious deformation or damage within 60min, meets JGT497-2016); airtightness: leakage rate <0.05%/min after 15min pressure holding at ±2500Pa (ASME N510), leakage rate <0.1%/min after 60min pressure holding at 1000Pa (JGT497-2016); PAO penetration <0.01% (ISO14644); sampling, pressure and disinfection testing can be performed inside the cleanroom (in-situ testing and in-situ disinfection)
Product Configuration (Material / Structure, etc.): 2.0mm thick SUS304 stainless steel box body, pressure interface overall continuous full welding; standard dry-seal HEPA filter (integrally molded PU gasket, high-quality EPDM gasket optional); gel-seal HEPA filter optional; various return air panel forms (inner waist-round holes / built-in louvers); filter installation limit design; installation methods: top / side-wall / under isolation bed, exhaust methods: side connection / top connection
DETAILS INTRODUCTION
Product Features:
Used for side-wall exhaust protection filtration: air discharged from biological laboratories or negative pressure isolation wards is filtered through HEPA filters before safe discharge, complying with regulatory requirements; box body adopts full-welded structure with high-quality SUS304 material, reasonable structural design and good welding process, ensuring operational stability and airtightness; in-situ disinfection can be performed before and after HEPA filter installation, complying with WHO Laboratory Biosafety Manual requirements; pre-filter installed on inlet panel, HEPA filter with special biosafety design optional inside the box; the entire unit can pass on-site PAO test at design air volume, meeting ISO14644 requirements.
Applications:
High-level biological laboratories, biopharmaceutical cleanrooms, infectious disease negative pressure isolation wards, etc.; can be side-wall mounted or installed on top walls.
RELATED PRODUCTS
Solution Provider for Building High‑Quality Air Ecological Environments
Isabella Tian
Business Director, Overseas Business Department
Annie Qin
Sales Director, Overseas Business Department
Address
503, 5th Floor, Headquarters International, Han Street, Wuchang District, Wuhan City, China
MESSAGECopyright © Royal Power (Wuhan) Co., Ltd. All Rights Reserved.
Telephone:
E-mail:
Message:
导航下拉添加类名.active
在线客服添加返回顶部
页面顺滑的滚动
右侧在线客服样式 1,2,3 3
图片alt标题设置: Royal Power
表单验证提示文本: Content cannot be empty!
CSS / JS 文件放置地